Friday, 22 April 2016

DPMS CENTRALISED CLEAN ROOM MONITORING SYSTEM

Whether you periodically certify your clean areas, continuously monitor them, or both, a Axelcon cleanroom particle counter can help you simplify your task, while staying in compliance and control. Axelcon products are specifically designed to meet the rigid requirements for Life Science and Electronics applications.


DPMS CENTRALISED CLEAN ROOM MONITORING SYSTEM


Accel DPMS is Centralized Clean Room Monitoring System that simultaneously, effectively, accurately and conveniently monitor the Differential Pressure, Temperature and RH in multiple clean rooms in the Pharma plant. It can be installed at entrances to clean rooms and other controlled environments.

SOFTWARE FEATURES:

Software Architecture
Multiple Clean rooms & Multiple Plants can be monitored centrally
Alarm & Alerts
Alarm & Alerts by way of Pop ups, Email & SMS can be sent to multiple authorities
Interface
Cloud Enabled Web Interface
Database
SQL Server
Audit Trail
Database (SQL) & GUI both supports audit trail
Reports
MIS Reports & Graphs for audit & analysis, 
Also value added Cutomization of reports are possible


FEATURES & BENEFITS:

  • Accurate & reliable logging of data at user Programmble Time Intervals
  • Easy Annual Callibration Process
  • Value Added MIS Reports & Graphs for Audit & Analysis


TECHNICAL SPECIFICATIONS:
Description
Display
Seven Segment 4 digit Display 
Row1 : Time Row2: Process Value
LED Indication
Channel Number, Alarm : HighLow, Memory Full Alarm, Negative Sign, Unit's Parameter (Pascalimm WC, °c/°F, %RH)
Transaction Capacity
10,000
Number of Channels
3
Channel Types
1. Differential Pressure 
2. Temperature 
3. Relative Humadity
Sensor Types
1. Differential Pressure (Internal Analog Sensor) 
2. Temperature Sensor extrenal : PT100, 4-20mA, 0-1V (Factory Set) 
3. Humadity Sensor external : 0-1V, 0-3.3V, 4-20mA (Factory Set)
Input Range Specification
1. Differential Pressure : (0 to 100mm WC) (Inbuilt) 
2. Temperature : PT100 (-090°C to 390°C) 
3. Relative Humadity : (0 to 100% RH)
Channel Resolution
1. Differential Pressure : 0.1mm WC 
2. Temperature: 0.1°C (depend on sensor) 
3. Relative Humadity : 0.1% RH (depend on sensor)
Keypad
4 keys (Menu, Up, Down, Enter)
Communication Port
2 No. RS-485 (1* RS-485 for PC Comm. & 2* for External Display)
Alarm Output
External potential free relay output for external Hooter Buzzer

Thursday, 21 April 2016

HYGRO I TEMPERATURE-HUMIDITY HYGROMETER

Hygrometers are essential device for pharmaceuticals because moisture in environment causes great effect on pharmaceutical products during manufacturing. Relative humidity of atmosphere is measured by the hygrometer in percentage. A hygrometer is weather instrument used to measure the amount of humidity in the atmosphere. There are two main types of hygrometers – a dry and wet bulb psychrometer and a mechanical hygrometer. According to their names dry bulb remains dry in the air and wet bulb is surrounded by a cotton wick that is dipped in the water. Wet bulb plays main role in the measurement of the humidity.
How do Hygrometers Work?

Hygrometer works on the phenomenon called evaporative cooling. When water evaporates from any surface, it becomes cool because water molecules take heat energy from the surface during the evaporation. Due to this cooling effect wet bulb always shows low temperature than the dry bulb. You can understand this with the conditions when you are felling very hot and you take bath with water. Water evaporates from our body taking some heat and you feel cool for some time.

Evaporation of water from the surface of wet bulb is inversely proportional to the humidity in the atmosphere. In dry atmosphere when humidity is low, the evaporation of water will high resulting the more decrease in wet blub temperature. But when atmosphere is humid having higher humidity, the evaporation of water from wet bulb remains low resulting the less decrease in the wet bulb temperature. At 100 percent humidity the temperature of dry and wet bulb will be same due to no water evaporation from the wet bulb hence no cooling effect occurs.

 

HYGRO I

TEMPERATURE-HUMIDITY HYGROMETER


Axelcon launches Temperature Humidity Hygrometer HYGRO-I with a fast response digital thermo hygrometer (indicator) used for measuring of temperature & relative humidity content in the atmosphere. It has jumbo 2 line display along with clock & date function. It is easy to operate & ensures most accurate measurements. It is mainly used in household, greenhouses & saunas for indoor/outdoor temp.-humidity measurements.

 
Hygrometer Working Principles

 

 

KEY FEATURES:

  • Simultaneous Indication of Temperature, Humidity & Clock
  • Temperature Unit Selection: °C / °F
  • 2 Mode of time Display: 12h/ 24h
  • Calendar with Alarm Clock function with Alarm adjustment
  • User End Calibration facility with adjustable potentiometer
  • Memory of MAX / MIN value of Temperature & Humidity
  • Low maintenance cost and longer service life

APPLICATION AREAS:


  • Laboratories
  • Humidors
  • Greenhouses
  • Homes & Offices
  • Humidity maintenance in museums and residential areas